The SolaX X3 Retro Fit is the ideal solution to modernize your solar installation. This hybrid inverter easily integrates with your existing system to store excess solar production in a battery, ensuring continuous power supply in any circumstance.
Why choose the SolaX X3 Retro Fit?
Key advantages:
SolaX X3 Retro Fit: The future of solar energy, today.

SolaX Power is pleased to announce the release of its new X3 Retro Fit. Generate energy from your solar panels during the day. Once the background charge has been satisfied, the intelligent SolaX X3 Retro Fit will direct excess energy into your battery for later use. Allowing you to make the most of your generated energy. If your home suffers a loss of power, the X3 Retro Fit then returns the stored energy to the home, ensuring you're never left in the dark even during a power cut.
The SolaX X3 Retro-Fit can be installed alongside any string inverter on the market today, allowing you to switch to solar battery storage without changing your existing installation. You also benefit from the added advantage of a backup power supply, enabling you to stay powered during a power cut.
With the SolaX X3 Retro-Fit, you can be sure you'll never be without power, even during a power cut. A backup power supply or "EPS" switch (only available on "E" models) allows the X3 Retro-fit to operate completely off-grid, meaning that all the energy you've stored on your batteries will now be used in the event of a power cut.
The X3 Retro-Fit is IP65-rated, which means it can be installed indoors or outdoors, giving you the choice of where to install the system.
| C OUTPUT |
| AC power rating (VA) |
| 10000 |
| AC power max. (VA) |
| 10000 |
| Nominal mains voltage (AC voltage range) (V) |
| 400V/230VAC; 380/220VAC |
| Nominal mains frequency/range (Hz) | 50/60 |
| Nominal AC current (A) | 14,5 |
| (A) | 16 |
| Displacement power factor |
| .8 leading to 0.8 trailing |
| THDi, rated power(%) | <2 |
| AC INPUT |
| Max. AC apparent power [VA] | 10000 |
| Max. | |
| AC current [A] | 16 |
| Nominal mains voltage(AC voltage range) [V] | 400V/230VAC ; |
| 380/220VAC |
| Nominal mains frequency/frequency range [Hz] | 50/60 |
| BATTERY |
| Battery voltage range [V] | 160-800 |
| Max. continuous charging/discharging current |
| 35 |
| ommunication interfaces | CAN / RS485 |
| Reverse connection protection | Yes |
| OFF-GRADE |
| (WITH BATTERY) |
| MAX. apparent power. | |
| continuous [VA] | 10000 |
| Nominal voltage [V],Frequency [Hz] | 400V/230VAC ; 380/220VAC |
| MAX. continuous current | 14,5 |
| eak apparent power [VA] | 10000 60 |
| Switching time [ms] | <1.5 |
| THDv, linear load [%] | <2 |
| Switching device | External |
| Three unbalanced phases | Yes |
| EFFICIENCY |
| Max. | |
| Battery charging efficiency (GRID to BAT) | 96,00 |
| Max. efficiency | |
| to BAT | |
| Battery discharge efficiency (BAT to AC) | 96,50 |
| POWER CONSUMPTION |
| Standby power consumption (Night) [W] | <25 for warm standby, <3 for cold standby |
| AND PROTECTION |
| Overvoltage and undervoltage protectionvoltages | Yes |
| Ground fault protection monitoring | Yes |
| Mains protection | Yes |
| STANDARD |
| Safety | IEC62477 |
| EN 61000-6-1 / EN 61000-6-2 / EN 61000-6-3 |
| Certification |
| 0126-1-1 A1:2012 / VDE-AR-N 4105 / G98 / AS4777 / EN50549/ CEI 0-21 |
| ENVIRONMENTAL LIMIT |
| Degree of protection (according to IEC60529) | IP65 |
| Operating temperature range [°C] |
| ~ +60 (derating to +45) |
| Maximum operating altitude [m] | <2000 |
| Humidity [%] |
| (condensation) |
| Storage temperature [°C] |
| 20 ~ +60 |
| Typical noise emission [dB] | 40 |
| DIMENSIONS AND WEIGHT |
| Dimensions [mm] | 457 x 654 x 228 |
| Weight [kg] | 38 |
| Cooling concept | Natural |
| Topology | Non-isolated |
| Communication interfaces | Ethernet |
| Pocket WiFi (optional) Pocket LAN (optional) Pocket GPRS (optional) DRM USB ISO alarm CT |
| LCD display | Yes |